svg

System administrator info

    mail: srvsysinfo@gmail.com

    HPE Smart Storage Administrator (HPE SSA) CLI

    VMware / 19.03.2022

    Prerequisiti:

    hpssacli

    HPE Smart Array storage controller
    The HPE Smart Storage Administrator CLI (HPE SSACLI) is a commandline-based disk configuration program that helps you configure, manage, diagnose, and monitor HPE ProLiant Smart Array Controllers and now other storage devices as well, such as host bus adapters (HBAs), HPE Storage controllers, and future devices such as SCSI Express drives, and SAS switch devices. HPE SSACLI replaces the existing HP Array Configuration CLI Utility, or ACUCLI, with an updated design and will deliver new features and functionality for various Smart Storage initiatives as they come online. HPE Smart Array Advanced Pack 1.0 and 2.0 features are now part of the baseline features of HPE SSACLI, with the appropriate firmware. HPE SSACLI will allow you to configure and manage your storage as before, but now with additional features, abilities, and supported devices.

    Show configuration
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl all show config
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show config

    Controller status
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl all show status
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show status

    Show detailed controller information for all controllers
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl all show detail
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show detail

    Show detailed controller information for controller in slot 0
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 show detail

    Rescan for New Devices
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli rescan
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli rescan

    Physical disk status
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd all show status

    Show detailed physical disk information
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd all show detail

    Logical disk status
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld all show status

    View Detailed Logical Drive Status
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 show

    Create New RAID 0 Logical Drive
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0

    Create New RAID 1 Logical Drive
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1

    Create New RAID 5 Logical Drive
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5

    Delete Logical Drive
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 delete
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 delete

    Add New Physical Drive to Logical Volume
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7

    Add Spare Disks
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7

    Enable Drive Write Cache
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=enable
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify dwc=enable

    Disable Drive Write Cache
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=disable
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify dwc=disable

    Erase Physical Drive
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd 2I:1:6 modify erase
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd 2I:1:6 modify erase

    Turn on Blink Physical Disk LED
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=on
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 modify led=on

    Turn off Blink Physical Disk LED
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=off
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 modify led=off

    Modify smart array cache read and write ratio (cacheratio=readratio/writeratio)
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify cacheratio=100/0
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify cacheratio=100/0

    Enable smart array write cache when no battery is present (No-Battery Write Cache option)
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify nbwc=enable
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify nbwc=enable

    Disable smart array cache for certain Logical Volume
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable

    Enable smart array cache for certain Logical Volume
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable

    Enable SSD Smart Path
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=enable
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 array a modify ssdsmartpath=enable

    Disable SSD Smart Path
    ESXi 5.5 -> /opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=disable
    ESXi 6.5 -> /opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 array a modify ssdsmartpath=disable